Open links in new tab
  1. Unistrut Properties Calculation | Eng-Tips

    Aug 11, 2009 · I have a project in Los Angeles in which I have specified a considerable amount of unistrut. I specified the unistrut based on the published allowable values in the Unistrut catalog. LA …

  2. Unistrut Yield Strength | Eng-Tips

    Nov 14, 2016 · Unistrut reported to me that their Unistrut steel is 33 ksi steel that has been cold rolled to 42 ksi. Does that happen because of compression during the cold rolling process? If not, how, then is …

  3. Unistrut Weld Detail | Eng-Tips

    Feb 12, 2019 · What do you guys think about this detail? The legs of the unistrut are facing downwards. The load is only about 150bs. The existing unistruts are already welded in this manner so I am trying …

  4. Unistrut P1000 (or other) esr report | Eng-Tips

    Feb 12, 2016 · I'm working on a project in Anaheim, CA involving cable trays and unistruts. My boss, the structural principal at our firm, recently mentioned that we should mention the evaluation report since …

  5. NFPA #13, Trapeze Hangers & Unistrut. | Eng-Tips

    May 23, 2008 · I would also note that unistrut (generic) is NOT listed in any NFPA "tables". So while you see NFPA 13 showing examples of how to determine the section moduls for and angle iron trapeze …

  6. P1001 Unistrut Design for Ceiling Mounted 2-tons Cath Lab

    Jan 7, 2024 · Hi Everyone, Thanks in advance for your valuable time and feedback. A bit of background: I am a junior engineer, fresh out of college, and have been given the opportunity to design a unistrut …

  7. Connecting threaded rod to Z-purlins? | Eng-Tips

    Aug 17, 2021 · We have some threaded rods we need to hang from Z-purlins (5 degree incline). Load around 1kN per rod. What's the best way to attach them? The recommendation is always to hang …

  8. Uni-strut and clamps used as fire sprinkler pipe hangers

    May 11, 2009 · WE are seeing more and more cases of unistrut type systems fastening sprinkler piping to building structure. If oriented so that piping is not hanging down against the clamp, the shear or …

  9. Unistrut in Torsion | Eng-Tips

    Jun 10, 2025 · Unistrut is setup so that local buckling is probably a non-issue. I certainly don't go out of my way to use unistrut in torsion for primary loads but, for small stuff, I'm sure it works. .unistrut is …

  10. Strength of unistrut section | Eng-Tips

    Sep 9, 2004 · I been trying to figure out the strength of a channel shape unistrut bar bolted on a rolling load table, which will be subjected to a concentrated load applied through a ball screw. Would some …