  1. wiring - Can I use a double pole breaker in a slot that allows tandem ...

    Jan 27, 2024 · A half height 2-pole breaker cannot be put iinto two half height slots that are on the same leg. Like my GE panel I am sure the half height slots have a mechanical excluder which prevents the …

  2. electrical - What is the purpose of a double pole breaker for separate ...

    A handle-tied breaker pair ("tie-bar breaker") provides common shutoff (which is required for MWBC) but does not provide common trip (which is not required for MWBC). In other words, a double breaker …

  3. How much current can my double pole breaker supply?

    Oct 9, 2020 · I originally planned to install a subpanel and feed it 90 amps. I thought I could do this by putting a 90A double-pole breaker in my main panel and feeding off that. What I was told was …

  4. Why is my double-pole 15 amp breaker/circuit tripping?

    Jan 15, 2024 · A double pole/single switch breaker can be for a 240 volt circuit or a multi wire branched circuit ( two 120v circuits sharing a neutral). Possible someone changed an outlet/receptacle and did …

  5. 14/3 Wire + Double Pole Breaker, Two 120v Circuits?

    Apr 26, 2020 · At the panel, a double pole 15 amp breaker with 14/3 wire is clearly labeled and dedicated to the room in question. The panel was upgraded within the last 30 years or so by a …

  6. Installing 4 baseboard heaters on a 20A double pole circuit

    Nov 6, 2023 · 1 I am looking for some help with configurations on installing 4 baseboard heaters on a 20 amp double pole breaker with 12/2 wires. My current set up is all four baseboard heaters are hooked …

  7. What is a tandem breaker (aka duplex, cheater, twin, double-stuff, etc.)?

    As far as I know all mfg's call there 240 breakers double pole, and tandem or double stuff are on the same pole. With tandem breakers they Cannot be used with a multi wire branch circuit because that …

  8. Double-pole GFCI breaker on MWBC - Home Improvement Stack …

    Oct 27, 2024 · Can I use this with a double-pole GFCI breaker in the panel (or combined GFCI+AFCI)? Uses will be for power tools, battery chargers, interior lights, and exterior lights. Will I have problems …

  9. Double-pole breaker but all 120 V receptacles [duplicate]

    Oct 31, 2022 · A double-pole breaker protects two hot 120V (relative to neutral) lines on opposite legs. So the two hot wires in a double-pole breaker (excluding a tandem double half-size breaker which is …

  10. Can two circuits share a neutral? - Home Improvement Stack Exchange

    In newer houses The two circuits must be on a double pole breaker for the smallest gauge wire used in the two circuits (e.g., 14 Ga. ==> 15 amps)In older houses code did not require the double pole or …